Release Notes OC32 3.23 (en)
OC32 3.23 Firmware
- Added: TMxx Feedback instruction
- Added: NSA instruction
OC32Config 3.23 - Added: TMxx Feedback instruction
- Added: NSA instruction
- Bugfix: Loading and reading back instructions did not work correctly in some cases.
Corrected.
Please note: To use the functions below, your RM-C or RM-U must be equipped with at least firmware 1.42 or higher, and your OC32 must be equipped with at least firmware 3.23 or higher!
TMxx Feedback
The TMxx Feedback instruction sends a feedback message to the host
system. If this system is an RM-C or RM-U with at least firmware version 1.42, this
RM-x will translate the feedback and forward it as a “switch event” (feedback,
occupancy detection) as if it originated from a TM-H, TM44, or UCCI. This makes it
possible to send information from the OC32 to control software that is unable to
process OC32 feedbacks, but is able to receive Dinamo occupancy detections.
A TMxx Feedback from the OC32 has the parameters “Feedback#”, “Module#”, and “State”
Module# is the virtual TM-H/UCCI module 0..15
Feedback# is the virtual occupancy detector 0..127 within the Module
State is the new state: 0 = inactive, 1 = active
Module#,Feedback# forms an 11-bit address 0..2047. When using this mechanism,
it is intended that you use a feedback from your Dinamo address range that is not already
used by a TM-H, UCCI, or TM44.
The numbering of Module# and Feedback# runs from 0..15 or 1..16 and from 0..127 or
1..128, depending on the “Start numbering at 1” checkbox in OC32Config.
NSA
OC32 instructions make it possible to control “Pins” from other “Pins” using
various instructions.
With the Network SetAspect instruction, it is now also possible to control other
OC32s from an OC32. With the “Network SetAspect” instruction, you give a “SetAspect”
instruction to another OC32 “Module”. The condition is that there is an RM-C or RM-U in the
system with firmware 1.42 or higher that controls the OC32s.
The NSA instruction has the parameters “Pin#”, “Module#”, and “Aspect”
Module# can have the values 0..95 or 1..96, depending on the “Start
numbering at 1” checkbox.
If the RM-x is set to basic OC32 Addressing, the system has a maximum of 16 OC32
modules and you can use Module 0..15 (1..16). You can enter other addresses,
but they will not work. If you have a dual-bus system in this case, you can use Module 0..31
.
If the RM-x is set to eXtended Addressing, you can use Module 0..47 (1..48) and in
a dual-bus system address 0..95 (1..96).