{"id":4379,"date":"2025-11-11T18:36:51","date_gmt":"2025-11-11T17:36:51","guid":{"rendered":"https:\/\/dinamobesturing.nl\/firmware\/oc32-3-21\/"},"modified":"2026-04-21T20:16:28","modified_gmt":"2026-04-21T18:16:28","slug":"oc32-3-21","status":"publish","type":"firmware","link":"https:\/\/dinamobesturing.nl\/fr\/firmware\/oc32-3-21\/","title":{"rendered":"OC32 3.21"},"content":{"rendered":"\n<h2 class=\"wp-block-heading\" id=\"Overzicht_wijzigingen\">Aper\u00e7u des modifications<a href=\"https:\/\/dinamousers.net\/OC32+Release+Notes+3.21_nl#Overzicht_wijzigingen\" target=\"_blank\" rel=\"noopener\"><\/a><\/h2>\n\n<h4 class=\"wp-block-heading\" id=\"OC32_3\\.21B_Firmware\">Firmware OC32 3.21B<a href=\"https:\/\/dinamousers.net\/OC32+Release+Notes+3.21_nl#OC32_3.21B_Firmware\" target=\"_blank\" rel=\"noopener\"><\/a><\/h4>\n\n<ul class=\"wp-block-list\">\n<li>Correctif de bug Commande OC32 SetAspect (version courte)<\/li>\n<\/ul>\n\n<p>Cette commande ne semblait pas fonctionner correctement. <strong>L\u2019erreur est donc \u00e9galement pr\u00e9sente dans les anciens OC32 tels que le 3.20.<\/strong> Cela pose probl\u00e8me, entre autres, dans iTrain 5.1.11. Ce probl\u00e8me sera contourn\u00e9 par iTrain dans les versions ult\u00e9rieures. Il est bien entendu pr\u00e9f\u00e9rable de pr\u00e9venir cela en installant ce correctif.  <\/p>\n\n<h4 class=\"wp-block-heading\" id=\"OC32_3\\.21A_Firmware\">Firmware OC32 3.21A<a href=\"https:\/\/dinamousers.net\/OC32+Release+Notes+3.21_nl#OC32_3.21A_Firmware\" target=\"_blank\" rel=\"noopener\"><\/a><\/h4>\n\n<ul class=\"wp-block-list\">\n<li>Ajout de l\u2019adressage \u00e9tendu forc\u00e9 (Enforced eXtended Addressing) OC32<\/li>\n<\/ul>\n\n<p>Avec ce firmware, les modules OC32 peuvent \u00eatre configur\u00e9s dans un nouveau mode d\u2019adressage \u00e9tendu forc\u00e9. Cet adressage est principalement destin\u00e9 \u00e0 \u00eatre utilis\u00e9 avec le firmware RM-x 1.41 (et versions ult\u00e9rieures). <\/p>\n\n<p><strong>OC32\/NG :<\/strong><br\/>Les commutateurs DIP 5 et 6 ont d\u00e9sormais une fonction :<\/p>\n\n<ul class=\"wp-block-list\">\n<li>Si les commutateurs DIP 5 et 6 sont tous deux sur OFF, le module fonctionne comme d\u2019habitude.<\/li>\n\n\n\n<li>Si au moins l\u2019un des commutateurs DIP 5 ou 6 est sur ON, les 6 commutateurs DIP forment un adresse \u00e9tendue (eXtended Address) de 0 \u00e0 47. Le module r\u00e9pond alors <strong>exclusivement<\/strong> aux paquets au format d\u2019adressage \u00e9tendu OC32. La partie adresse de base (Basic Address) du message peut alors avoir n\u2019importe quelle valeur de 0 \u00e0 15, tant que l\u2019adresse \u00e9tendue correspond \u00e0 la valeur d\u00e9finie par les commutateurs DIP.  <\/li>\n\n\n\n<li>En mode d\u2019adressage \u00e9tendu forc\u00e9, le module ne r\u00e9pond pas aux paquets de diffusion \u00e9tendue (eXtended Broadcast) ni aux paquets de groupe \u00e9tendus (eXtended Group).<\/li>\n<\/ul>\n\n<p><strong>OC32 (non-NG) :<\/strong><\/p>\n\n<ul class=\"wp-block-list\">\n<li>Le module peut \u00eatre plac\u00e9 en \u00ab mode d\u2019adressage \u00e9tendu forc\u00e9 \u00bb par le biais de la configuration.<\/li>\n\n\n\n<li>Lorsque ce mode est activ\u00e9, le module fonctionne de mani\u00e8re identique \u00e0 un OC32\/NG avec les commutateurs DIP 5 et 6 sur ON. Le module fonctionne alors strictement en mode d\u2019adressage \u00e9tendu et l\u2019adresse \u00e9tendue peut \u00eatre r\u00e9gl\u00e9e avec les commutateurs DIP entre 0 et 15. <\/li>\n\n\n\n<li>Ce param\u00e8tre logiciel fonctionne \u00e9galement sur l\u2019OC32\/NG, mais il n\u2019y a aucune utilit\u00e9 pratique, car les commutateurs DIP 5 et 6 font la m\u00eame chose, mais de mani\u00e8re mat\u00e9rielle. Si le param\u00e8tre logiciel est utilis\u00e9 dans l\u2019OC32\/NG, cela signifie que le fonctionnement est identique que les commutateurs DIP 5 et 6 soient tous deux sur ON ou tous deux sur OFF. <\/li>\n<\/ul>\n\n<p><br\/><strong>ATTENTION : CE FIRMWARE EST EXCLUSIVEMENT EXP\u00c9RIMENTAL !!<\/strong><\/p>\n\n<p>Commutateurs DIP OC32\/NG avec firmware 3.21A :<\/p>\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><tbody><tr><td>Adresse \u00e9tendue<\/td><td>SW1<\/td><td>SW2<\/td><td>SW3<\/td><td>SW4<\/td><td>SW5<\/td><td>SW6<\/td><\/tr><tr><td>0<\/td><td>ON<\/td><td>ON<\/td><td>ON<\/td><td>ON<\/td><td>ON<\/td><td>ON<\/td><\/tr><tr><td>1<\/td><td>OFF<\/td><td>ON<\/td><td>ON<\/td><td>ON<\/td><td>ON<\/td><td>ON<\/td><\/tr><tr><td>2<\/td><td>ON<\/td><td>OFF<\/td><td>ON<\/td><td>ON<\/td><td>ON<\/td><td>ON<\/td><\/tr><tr><td>..<\/td><td>\u00a0<\/td><td>\u00a0<\/td><td>\u00a0<\/td><td>\u00a0<\/td><td>\u00a0<\/td><td>\u00a0<\/td><\/tr><tr><td>15<\/td><td>OFF<\/td><td>OFF<\/td><td>OFF<\/td><td>OFF<\/td><td>ON<\/td><td>ON<\/td><\/tr><tr><td>16<\/td><td>ON<\/td><td>ON<\/td><td>ON<\/td><td>ON<\/td><td>OFF<\/td><td>ON<\/td><\/tr><tr><td>17<\/td><td>OFF<\/td><td>ON<\/td><td>ON<\/td><td>ON<\/td><td>OFF<\/td><td>ON<\/td><\/tr><tr><td>..<\/td><td>\u00a0<\/td><td>\u00a0<\/td><td>\u00a0<\/td><td>\u00a0<\/td><td>\u00a0<\/td><td>\u00a0<\/td><\/tr><tr><td>23<\/td><td>OFF<\/td><td>OFF<\/td><td>OFF<\/td><td>OFF<\/td><td>OFF<\/td><td>ON<\/td><\/tr><tr><td>24<\/td><td>ON<\/td><td>ON<\/td><td>ON<\/td><td>ON<\/td><td>ON<\/td><td>OFF<\/td><\/tr><tr><td>25<\/td><td>OFF<\/td><td>ON<\/td><td>ON<\/td><td>ON<\/td><td>ON<\/td><td>OFF<\/td><\/tr><tr><td>..<\/td><td>\u00a0<\/td><td>\u00a0<\/td><td>\u00a0<\/td><td>\u00a0<\/td><td>\u00a0<\/td><td>\u00a0<\/td><\/tr><tr><td>47<\/td><td>OFF<\/td><td>OFF<\/td><td>OFF<\/td><td>OFF<\/td><td>ON<\/td><td>OFF<\/td><\/tr><\/tbody><\/table><\/figure>\n\n<h4 class=\"wp-block-heading\" id=\"OC32Config_3\\.21B\">OC32Config 3.21B<a href=\"https:\/\/dinamousers.net\/OC32+Release+Notes+3.21_nl#OC32Config_3.21B\" target=\"_blank\" rel=\"noopener\"><\/a><\/h4>\n\n<ul class=\"wp-block-list\">\n<li>Correctif : La lecture des param\u00e8tres du port d\u2019accessoires s\u00e9rie pouvait, dans certains cas, entra\u00eener le blocage d\u2019OC32Config.<\/li>\n<\/ul>\n\n<h4 class=\"wp-block-heading\" id=\"OC32Config_3\\.21A\">OC32Config 3.21A<a href=\"https:\/\/dinamousers.net\/OC32+Release+Notes+3.21_nl#OC32Config_3.21A\" target=\"_blank\" rel=\"noopener\"><\/a><\/h4>\n\n<ul class=\"wp-block-list\">\n<li>Journalisation am\u00e9lior\u00e9e. Tant lors de l\u2019utilisation du tunneling Dinamo que de la communication directe. Diverses am\u00e9liorations en arri\u00e8re-plan.  <\/li>\n<\/ul>\n\n<h4 class=\"wp-block-heading\" id=\"OC32Config_3\\.21\">OC32Config 3.21<a href=\"https:\/\/dinamousers.net\/OC32+Release+Notes+3.21_nl#OC32Config_3.21\" target=\"_blank\" rel=\"noopener\"><\/a><\/h4>\n\n<ul class=\"wp-block-list\">\n<li>Ajout de l\u2019adressage \u00e9tendu forc\u00e9 OC32. Dans l\u2019onglet \u00ab General \u00bb, une option \u00ab Enforced eXtended Address \u00bb a \u00e9t\u00e9 ajout\u00e9e. Si cette option est coch\u00e9e et \u00e9crite dans l\u2019OC32, celui-ci fonctionne <strong>exclusivement<\/strong> en mode d\u2019adressage \u00e9tendu, l\u2019adresse \u00e9tendue \u00e9tant d\u00e9finie par les commutateurs DIP. Ce param\u00e8tre est sp\u00e9cifiquement destin\u00e9 aux OC32 non-NG.   <\/li>\n<\/ul>\n","protected":false},"featured_media":0,"template":"","meta":{"_acf_changed":false},"firmware-producten":[258],"class_list":["post-4379","firmware","type-firmware","status-publish","hentry","firmware-producten-actueel-oc32"],"acf":[],"jetpack_sharing_enabled":true,"_links":{"self":[{"href":"https:\/\/dinamobesturing.nl\/fr\/wp-json\/wp\/v2\/firmware\/4379","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/dinamobesturing.nl\/fr\/wp-json\/wp\/v2\/firmware"}],"about":[{"href":"https:\/\/dinamobesturing.nl\/fr\/wp-json\/wp\/v2\/types\/firmware"}],"wp:attachment":[{"href":"https:\/\/dinamobesturing.nl\/fr\/wp-json\/wp\/v2\/media?parent=4379"}],"wp:term":[{"taxonomy":"firmware-producten","embeddable":true,"href":"https:\/\/dinamobesturing.nl\/fr\/wp-json\/wp\/v2\/firmware-producten?post=4379"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}