{"id":4375,"date":"2025-11-11T18:36:51","date_gmt":"2025-11-11T17:36:51","guid":{"rendered":"https:\/\/dinamobesturing.nl\/firmware\/oc32-3-21\/"},"modified":"2026-04-21T20:16:16","modified_gmt":"2026-04-21T18:16:16","slug":"oc32-3-21","status":"publish","type":"firmware","link":"https:\/\/dinamobesturing.nl\/de\/firmware\/oc32-3-21\/","title":{"rendered":"OC32 3.21"},"content":{"rendered":"\n<h2 class=\"wp-block-heading\" id=\"Overzicht_wijzigingen\">\u00c4nderungs\u00fcbersicht<a href=\"https:\/\/dinamousers.net\/OC32+Release+Notes+3.21_nl#Overzicht_wijzigingen\" target=\"_blank\" rel=\"noopener\"><\/a><\/h2>\n\n<h4 class=\"wp-block-heading\" id=\"OC32_3\\.21B_Firmware\">OC32 3.21B Firmware<a href=\"https:\/\/dinamousers.net\/OC32+Release+Notes+3.21_nl#OC32_3.21B_Firmware\" target=\"_blank\" rel=\"noopener\"><\/a><\/h4>\n\n<ul class=\"wp-block-list\">\n<li>Bugfix OC32 SetAspect-Kommando (Kurzversion)<\/li>\n<\/ul>\n\n<p>Dieses Kommando funktionierte offenbar nicht korrekt. <strong>Dies ist somit auch ein Fehler in \u00e4lteren OC32-Modulen wie 3.20.<\/strong> Dies f\u00fchrt unter anderem in iTrain 5.1.11 zu Problemen. In sp\u00e4teren Versionen wird iTrain dies umgehen. Besser ist es jedoch nat\u00fcrlich, dies durch die Installation dieses Bugfixes zu verhindern.  <\/p>\n\n<h4 class=\"wp-block-heading\" id=\"OC32_3\\.21A_Firmware\">OC32 3.21A Firmware<a href=\"https:\/\/dinamousers.net\/OC32+Release+Notes+3.21_nl#OC32_3.21A_Firmware\" target=\"_blank\" rel=\"noopener\"><\/a><\/h4>\n\n<ul class=\"wp-block-list\">\n<li>Hinzuf\u00fcgung OC32 Enforced eXtended Addressing<\/li>\n<\/ul>\n\n<p>OC32-Module k\u00f6nnen mit dieser Firmware in einen neuen \u201eEnforced eXtended Addressing Mode\u201c versetzt werden. Diese Adressierung ist prim\u00e4r f\u00fcr die Verwendung mit der RM-x Firmware 1.41 (und h\u00f6her) vorgesehen. <\/p>\n\n<p><strong>OC32\/NG:<\/strong><br\/>Die DIP-Schalter 5 und 6 haben nun eine Funktion:<\/p>\n\n<ul class=\"wp-block-list\">\n<li>Wenn die DIP-Schalter 5 und 6 beide auf OFF stehen, arbeitet das Modul wie gewohnt.<\/li>\n\n\n\n<li>Wenn mindestens einer der DIP-Schalter 5 oder 6 auf ON steht, bilden die 6 DIP-Schalter eine eXtended Address 0..47. Das Modul reagiert dann <strong>ausschlie\u00dflich<\/strong> auf Pakete im OC32 eXtended Addressing Format. Der Basic Address-Teil der Nachricht darf dann einen beliebigen Wert von 0..15 haben, solange die eXtended Address den mit den DIP-Schaltern eingestellten Wert hat.  <\/li>\n\n\n\n<li>Im Enforced eXtended Addressing Mode reagiert das Modul nicht auf eXtended Broadcast- und eXtended Group-Pakete.<\/li>\n<\/ul>\n\n<p><strong>OC32 (nicht-NG):<\/strong><\/p>\n\n<ul class=\"wp-block-list\">\n<li>Das Modul kann mittels Konfiguration in den \u201eEnforced eXtended Addressing Mode\u201c versetzt werden.<\/li>\n\n\n\n<li>Wenn dieser Modus aktiviert ist, arbeitet das Modul identisch zu einem OC32\/NG mit den DIP-Schaltern 5 und 6 auf ON. Das Modul arbeitet dann strikt im eXtended Addressing Mode und die eXtended Address kann mit den DIP-Schaltern zwischen 0 und 15 eingestellt werden. <\/li>\n\n\n\n<li>Diese Software-Einstellung funktioniert auch beim OC32\/NG, hat dort jedoch keinen praktischen Nutzen, da die DIP-Schalter 5 und 6 dasselbe bewirken, jedoch hardwareseitig. Wenn die Software-Einstellung im OC32\/NG verwendet wird, bedeutet dies, dass die Funktionsweise bei den DIP-Schaltern 5 und 6 sowohl auf ON als auch auf OFF identisch ist. <\/li>\n<\/ul>\n\n<p><br\/><strong>ACHTUNG: DIESE FIRMWARE IST AUSDR\u00dcCKLICH EXPERIMENTELL !!<\/strong><\/p>\n\n<p>DIP-Schalter OC32\/NG mit 3.21A Firmware:<\/p>\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><tbody><tr><td>eXtended Address<\/td><td>SW1<\/td><td>SW2<\/td><td>SW3<\/td><td>SW4<\/td><td>SW5<\/td><td>SW6<\/td><\/tr><tr><td>0<\/td><td>ON<\/td><td>ON<\/td><td>ON<\/td><td>ON<\/td><td>ON<\/td><td>ON<\/td><\/tr><tr><td>1<\/td><td>OFF<\/td><td>ON<\/td><td>ON<\/td><td>ON<\/td><td>ON<\/td><td>ON<\/td><\/tr><tr><td>2<\/td><td>ON<\/td><td>OFF<\/td><td>ON<\/td><td>ON<\/td><td>ON<\/td><td>ON<\/td><\/tr><tr><td>..<\/td><td>\u00a0<\/td><td>\u00a0<\/td><td>\u00a0<\/td><td>\u00a0<\/td><td>\u00a0<\/td><td>\u00a0<\/td><\/tr><tr><td>15<\/td><td>OFF<\/td><td>OFF<\/td><td>OFF<\/td><td>OFF<\/td><td>ON<\/td><td>ON<\/td><\/tr><tr><td>16<\/td><td>ON<\/td><td>ON<\/td><td>ON<\/td><td>ON<\/td><td>OFF<\/td><td>ON<\/td><\/tr><tr><td>17<\/td><td>OFF<\/td><td>ON<\/td><td>ON<\/td><td>ON<\/td><td>OFF<\/td><td>ON<\/td><\/tr><tr><td>..<\/td><td>\u00a0<\/td><td>\u00a0<\/td><td>\u00a0<\/td><td>\u00a0<\/td><td>\u00a0<\/td><td>\u00a0<\/td><\/tr><tr><td>23<\/td><td>OFF<\/td><td>OFF<\/td><td>OFF<\/td><td>OFF<\/td><td>OFF<\/td><td>ON<\/td><\/tr><tr><td>24<\/td><td>ON<\/td><td>ON<\/td><td>ON<\/td><td>ON<\/td><td>ON<\/td><td>OFF<\/td><\/tr><tr><td>25<\/td><td>OFF<\/td><td>ON<\/td><td>ON<\/td><td>ON<\/td><td>ON<\/td><td>OFF<\/td><\/tr><tr><td>..<\/td><td>\u00a0<\/td><td>\u00a0<\/td><td>\u00a0<\/td><td>\u00a0<\/td><td>\u00a0<\/td><td>\u00a0<\/td><\/tr><tr><td>47<\/td><td>OFF<\/td><td>OFF<\/td><td>OFF<\/td><td>OFF<\/td><td>ON<\/td><td>OFF<\/td><\/tr><\/tbody><\/table><\/figure>\n\n<h4 class=\"wp-block-heading\" id=\"OC32Config_3\\.21B\">OC32Config 3.21B<a href=\"https:\/\/dinamousers.net\/OC32+Release+Notes+3.21_nl#OC32Config_3.21B\" target=\"_blank\" rel=\"noopener\"><\/a><\/h4>\n\n<ul class=\"wp-block-list\">\n<li>Bugfix: Das Einlesen der Serial Accessory Port-Einstellungen konnte in manchen F\u00e4llen zum Absturz von OC32Config f\u00fchren.<\/li>\n<\/ul>\n\n<h4 class=\"wp-block-heading\" id=\"OC32Config_3\\.21A\">OC32Config 3.21A<a href=\"https:\/\/dinamousers.net\/OC32+Release+Notes+3.21_nl#OC32Config_3.21A\" target=\"_blank\" rel=\"noopener\"><\/a><\/h4>\n\n<ul class=\"wp-block-list\">\n<li>Verbesserte Protokollierung (Logging). Sowohl bei der Verwendung von Dinamo-Tunneling als auch bei direkter Kommunikation. Diverse Verbesserungen im Hintergrund.  <\/li>\n<\/ul>\n\n<h4 class=\"wp-block-heading\" id=\"OC32Config_3\\.21\">OC32Config 3.21<a href=\"https:\/\/dinamousers.net\/OC32+Release+Notes+3.21_nl#OC32Config_3.21\" target=\"_blank\" rel=\"noopener\"><\/a><\/h4>\n\n<ul class=\"wp-block-list\">\n<li>Hinzuf\u00fcgung OC32 Enforced eXtended Addressing. Auf der Registerkarte \u201eGeneral\u201c wurde die Option \u201eEnforced eXtended Address\u201c hinzugef\u00fcgt. Wenn diese Option markiert und auf den OC32 geschrieben wurde, arbeitet dieser <strong>ausschlie\u00dflich<\/strong> im eXtended Addressing Mode, wobei die eXtended Address \u00fcber die DIP-Schalter eingestellt wird. Diese Einstellung ist speziell f\u00fcr nicht-NG OC32-Module gedacht.   <\/li>\n<\/ul>\n","protected":false},"featured_media":0,"template":"","meta":{"_acf_changed":false},"firmware-producten":[257],"class_list":["post-4375","firmware","type-firmware","status-publish","hentry","firmware-producten-actueel-oc32"],"acf":[],"jetpack_sharing_enabled":true,"_links":{"self":[{"href":"https:\/\/dinamobesturing.nl\/de\/wp-json\/wp\/v2\/firmware\/4375","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/dinamobesturing.nl\/de\/wp-json\/wp\/v2\/firmware"}],"about":[{"href":"https:\/\/dinamobesturing.nl\/de\/wp-json\/wp\/v2\/types\/firmware"}],"wp:attachment":[{"href":"https:\/\/dinamobesturing.nl\/de\/wp-json\/wp\/v2\/media?parent=4375"}],"wp:term":[{"taxonomy":"firmware-producten","embeddable":true,"href":"https:\/\/dinamobesturing.nl\/de\/wp-json\/wp\/v2\/firmware-producten?post=4375"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}